The a stands for augmented and is a nod to cat6a s improved specifications compared with its predecessor the category 6 or cat6 cable.
Cat6 ethernet cable diameter.
Set your store to see local availability add to cart.
Cat 6 has to meet more stringent specifications for crosstalk and system noise than cat 5 and cat 5e.
Free delivery with 45 order.
24 7 gauge 8 wire cat6 ethernet cable white model 587528 3 4 97 4 97.
The cat6a doubles data transmission bandwidth from 250 to 500 mhz.
By doing so resistance is automatically reduced over the cable.
Decreases the chance of crosstalk interference.
It s theoretical top speed is 10 gbps over 100 meters.
The cost is about 20 35 higher than cat6 but the maximum cable length is 100 meters across all systems and conditions for gigabit ethernet.
Cat 6 supports 10 gigabit ethernet only up to 164 feet of cable length.
The category 6a or cat6a cable is the latest iteration of gigabit ethernet cabling.
And provides superior reliability and transmission.
Cat 6 cables technically support speeds up to 10gbps but only do so for up to 55 meters.
That speed comes with a price however as cat 6 cables are more expensive than cat 5 and cat 5e variants.
Commercial electric 3 ft.
Cat6 ethernet cable 1000ft insulated bare copper wire internet cable with noise reducing cross separator 550mhz 10 gigabit speed utp lan cable 1000 ft cmr yellow 4 8 out of 5 stars 249 132 99 132.
Notice the lower the gauge the higher the thickness.
Cat6a utp cable design differs among manufacturers.
Category 6 cable cat 6 is a standardized twisted pair cable for ethernet and other network physical layers that is backward compatible with the category 5 5e and category 3 cable standards.
Micro connectors inc 100 ft.
The category 6 augmented cable standard or cat 6a was created to further improve the performance of cat 6 ethernet cables using cat 6a enables 10 gigabit ethernet data rates over a single cable run up to 328 feet.
Specifications utp cat 6 cable db 100 ft 30 48 m db 100 m 328 ft mhz 14 pf ft 46 pf m nominal capacit ance nominal attenuation 100 ohms 15 ohms 68 insula tion bend radius nominal velocity of propa gation 0 90 2 3 cm time delay 46 lbs 20 9 kg per 1000 ft 304 8 m shipping weight per standardcoverage length awg diameter stranding.
To reduce resistance and allow for a better flow of electrons the diameter of the cable s conductor must be increased.
The outside diameter of cat6a f utp can be as large as 0 354 compared to 0 265 0 30 for cat6a f utp and 0 21 9 24 for cat6.